Tundra Space

Tundra Space

Clinical Research Directory

Browse clinical research sites, groups, and studies.

Back to Studies
NOT YET RECRUITING
NCT07555977
NA

SUPERSTAR: Aspiration vs. Stent Retriever in Anterior Circulation LVO

Sponsor: Shanghai Jiao Tong University Affiliated Sixth People's Hospital

View on ClinicalTrials.gov

Summary

This is a multicenter, open-label, blinded-endpoint, randomized controlled trial comparing super large bore catheter aspiration versus stent retriever thrombectomy as the first-line technique for anterior circulation large vessel occlusion in acute ischemic stroke. Eligible patients with acute ischemic stroke due to internal carotid artery intracranial segment and/or middle cerebral artery M1 occlusion will be randomized 1:1 to receive either aspiration using a super large bore catheter (inner diameter ≥0.080 inch) or stent retriever thrombectomy (allowing balloon guiding catheters or intermediate catheters with inner diameter \<0.080 inch). The primary outcome is the ordinal modified Rankin Scale score at 90 days post-procedure. Key secondary outcomes include the proportion of patients with mRS 0-2 at 90 days, change in NIHSS at 24 hours and 7 days, and various angiographic and safety endpoints. The trial plans to enroll 708 patients across approximately 30 centers in China. The total study duration is 24-36 months, with each patient participating for 3 months.

Official title: Super Large Bore Catheter Aspiration Versus Stent Retriever Thrombectomy as First Line Technique for Anterior Circulation Large Vessel Occlusion in Acute Ischemic Stroke

Key Details

Gender

All

Age Range

18 Years - Any

Study Type

INTERVENTIONAL

Enrollment

708

Start Date

2026-09-15

Completion Date

2028-03-30

Last Updated

2026-09-02

Healthy Volunteers

No

Interventions

PROCEDURE

Super Large Bore Catheter

The SLBC group may switch to different super large bore aspiration catheters. Once the aspiration catheter contacts the thrombus, continuous negative pressure aspiration is maintained for 1 minute. A total of at least three aspiration attempts should be performed using aspiration catheters of different inner diameters. If the catheter fails to contact the thrombus despite using different inner diameter catheters, or if complete recanalization is not achieved after three attempts, or if new embolization occurs in the M2 segment or other vascular territories, the investigator may decide, as deemed necessary, to continue attempting with the original device or to use other techniques and devices for recanalization. In cases where angiography shows that the thrombus has migrated forward and can no longer be aspirated using a super large bore catheter, and continued thrombectomy is judged necessary, other rescue techniques may be used.

PROCEDURE

Stent Retriever Thrombectomy

Stent retriever thrombectomy is performed as the first line approach. Allowed to employ adjunctive technology during the stent retriever passes according to physician preference, which may be combined with an aspiration catheter (inner diameter \< 0.080 inch). The use of a large-bore aspiration catheter (inner diameter \> 0.080 inch) is prohibited in this arm.