Clinical Research Directory
Browse clinical research sites, groups, and studies.
Using the Boneflo System During Orthopedic and Trauma Surgery: A Prospective Multicenter Study
Sponsor: Universität Duisburg-Essen
Summary
Critical bone defects, non-unions, and delayed bone healing remain major challenges in orthopedic and trauma surgery and often require bone grafting. While a patient's own bone (autograft) is considered the gold standard, its use is limited by donor-site morbidity and limited availability. Synthetic bone substitutes offer an alternative but mainly provide structural support and lack biological activity. This prospective multicenter pilot study evaluates the safety and feasibility of using the Boneflo® Tissue Collector System to biologically activate bone substitutes during surgery. The device collects the patient's own tissue, blood, and biologically active factors directly from the surgical site using a vacuum-assisted suction system with an integrated filter. This material is then used intraoperatively to coat and bioactivate bone substitute materials. In healing attempts, 50 patients with critical bone defects, non-unions, or impaired bone healing were treated across four centers. Various bone substitutes, including synthetic calcium phosphate materials, collagen-based scaffolds, and allografts, were used. The primary aim of the study was to evaluate device safety, intraoperative usability, handling, and applicability for coating and activating bone substitutes. The device was evaluated by orthopedic surgeons and other medical professionals, including nurses, physician assistants, and technical assistants. Furthermore, these data were supplemented with clinical outcome data from healing attempts, including wound healing and radiographic bone regeneration, assessed over a minimum six-month follow-up period.
Official title: Analysis of the Intraoperative Use and Handling of the Boneflo Tissue Collector System in Orthopedic and Trauma Surgery
Key Details
Gender
All
Age Range
18 Years - Any
Study Type
INTERVENTIONAL
Enrollment
100
Start Date
2024-07-01
Completion Date
2026-03-01
Last Updated
2026-05-01
Healthy Volunteers
No
Interventions
Intraoperative bioactivation of bone substitute materials using the Boneflo® Tissue Collector System.
During surgery, autologous tissue, blood, and biologically active components are collected from the surgical site under vacuum conditions with an integrated filter system using the BoneFlo tissue collector. The collected autologous material is used to coat and biologically enhance bone substitutes. Bone substitutes include calcium phosphate ceramics, collagen-based scaffolds, and allografts. This intervention is performed intraoperatively and aims to improve the biological activity of otherwise mainly osteoconductive materials.
Locations (1)
St. Marien-Hospital Mülheim an der Ruhr
Mülheim, Germany