Tundra Space

Tundra Space

Clinical Research Directory

Browse clinical research sites, groups, and studies.

Back to Studies
COMPLETED
NCT07562165
NA

Using the Boneflo System During Orthopedic and Trauma Surgery: A Prospective Multicenter Study

Sponsor: Universität Duisburg-Essen

View on ClinicalTrials.gov

Summary

Critical bone defects, non-unions, and delayed bone healing remain major challenges in orthopedic and trauma surgery and often require bone grafting. While a patient's own bone (autograft) is considered the gold standard, its use is limited by donor-site morbidity and limited availability. Synthetic bone substitutes offer an alternative but mainly provide structural support and lack biological activity. This prospective multicenter pilot study evaluates the safety and feasibility of using the Boneflo® Tissue Collector System to biologically activate bone substitutes during surgery. The device collects the patient's own tissue, blood, and biologically active factors directly from the surgical site using a vacuum-assisted suction system with an integrated filter. This material is then used intraoperatively to coat and bioactivate bone substitute materials. In healing attempts, 50 patients with critical bone defects, non-unions, or impaired bone healing were treated across four centers. Various bone substitutes, including synthetic calcium phosphate materials, collagen-based scaffolds, and allografts, were used. The primary aim of the study was to evaluate device safety, intraoperative usability, handling, and applicability for coating and activating bone substitutes. The device was evaluated by orthopedic surgeons and other medical professionals, including nurses, physician assistants, and technical assistants. Furthermore, these data were supplemented with clinical outcome data from healing attempts, including wound healing and radiographic bone regeneration, assessed over a minimum six-month follow-up period.

Official title: Analysis of the Intraoperative Use and Handling of the Boneflo Tissue Collector System in Orthopedic and Trauma Surgery

Key Details

Gender

All

Age Range

18 Years - Any

Study Type

INTERVENTIONAL

Enrollment

100

Start Date

2024-07-01

Completion Date

2026-03-01

Last Updated

2026-05-01

Healthy Volunteers

No

Interventions

OTHER

Intraoperative bioactivation of bone substitute materials using the Boneflo® Tissue Collector System.

During surgery, autologous tissue, blood, and biologically active components are collected from the surgical site under vacuum conditions with an integrated filter system using the BoneFlo tissue collector. The collected autologous material is used to coat and biologically enhance bone substitutes. Bone substitutes include calcium phosphate ceramics, collagen-based scaffolds, and allografts. This intervention is performed intraoperatively and aims to improve the biological activity of otherwise mainly osteoconductive materials.

Locations (1)

St. Marien-Hospital Mülheim an der Ruhr

Mülheim, Germany