Tundra Space

Tundra Space

Clinical Research Directory

Browse clinical research sites, groups, and studies.

Back to Studies
RECRUITING
NCT07567456
NA

Pulsatile Flushing Technique in Reducing Blockage of T-CVAD for Haemodialysis Patients

Sponsor: Queen Elizabeth Hospital, Hong Kong

View on ClinicalTrials.gov

Summary

This study investigates the effectiveness of pulsatile flushing techniques in reducing blockage in Tunnelled Central Venous Access Device (T-CVAD) among patients undergoing haemodialysis (HD) treatment at multiple renal centres within the Hospital Authority (HA) in Hong Kong. With limitation in single service protocol for each cluster of renal units, it is designed as a prospective, parallel, cluster non-randomised controlled trial involving 591 patients from 14 renal units. In order to identify the most effective flushing technique for T-CVAD maintenance, survival analysis on clinical effectiveness, in terms time-to-event blockage of the T-CVAD, among three trial arms: 1) Intervention Group A (IG-A) using pulsatile flushing technique with 0.4 second pause time interval; 2) Intervention Group B (IG-B) using pulsatile flushing technique with 1 second pause time interval; 3) Control Group (Con) using standard bolus flushing technique. The findings facilitate development of best practice for T-CVAD maintenance, optimise T-CVAD maintenance protocols, and ultimately improve patient outcomes. This groundbreaking study is expected to signify substantial progression in the nursing management of HD and T-CVAD.

Official title: Exploring the Effectiveness of Pulsatile Flushing Technique in Reducing Blockage of the Tunnelled Central Venous Access Device Among Haemodialysis Patients in Multiple Renal Centres in Hong Kong: A Cluster Non-Randomised Controlled Trial Study

Key Details

Gender

All

Age Range

18 Years - Any

Study Type

INTERVENTIONAL

Enrollment

591

Start Date

2026-02-02

Completion Date

2027-12

Last Updated

2026-05-11

Healthy Volunteers

No

Interventions

DEVICE

Pulsatile Flushing Technique (0.4s pause interval)

Pulsatile flushing technique consists of multiple small boluses injected intermittently with 0.4-second pauses between each bolus resulting in unsteady turbulent flow, performed by a renal nurse who passed a formal train-the-trainer program on "pulsatile flushing technique" taught and assessed by designated nurse consultant (renal care).

OTHER

Pulsatile Flushing Technique (1s pause interval)

Pulsatile flushing technique consists of multiple small boluses injected intermittently with 1-second pauses between each bolus resulting in unsteady turbulent flow, performed by a renal nurse who passed a formal train-the-trainer program on "pulsatile flushing technique" taught and assessed by designated nurse consultant (renal care).

DEVICE

Bolus Flushing Technique

Bolus flushing technique involves the continuous administration of a single, concentrated volume of flush solution resulting in consistent laminar flow

Locations (1)

Queen Elizabeth Hospital

Kowloon, Hong Kong