Clinical Research Directory
Browse clinical research sites, groups, and studies.
ASSESSMENT OF SIGNAL CONSISTENCY BETWEEN NEEDLE AND SURFACE ELECTRODES IN TIBIALIS ANTERIOR MUSCLE: A PILOT VALIDATON STUDY
Sponsor: Romatem Bursa Hospital
Summary
The aim of this study is to evaluate whether surface electrodes can record physiological muscle activity as accurately as the gold-standard needle electrodes in the tibialis anterior muscle using a diagnostic EMG device The aim of this pilot study is to investigate whether muscle activation data, similar to surface electromyography (SEMG), can be obtained by adjusting the measurement and recording parameters of standard Electroneuromyography (EMG) devices used routinely for diagnostic purposes. Although SEMG is considered the gold standard for the objective assessment of muscle activation, its clinical use in our country is limited due to the high cost of specialized hardware and software. In contrast, diagnostic EMG devices are widely available in many healthcare institutions. The research will be conducted on 30 healthy volunteers between the ages of 20 and 60. Participants will undergo lower extremity nerve conduction studies, reflex response measurements, and muscle activation assessments during voluntary isometric contractions of the m. tibialis anterior. Muscle activation will be recorded using the diagnostic EMG device via surface (adhesive and Ag/AgCl coated) electrodes and needle electrodes. The acquired EMG signals will be analyzed in terms of RMS (Root Mean Square), amplitude, and frequency parameters. The procedures performed within the scope of this study are standard practices carried out during routine EMG examinations. The only additional procedure specific to this research is the repetition of muscle activation measurements using different electrode systems. There is no invasive procedure involved in the surface electrode applications, and the needle electrode application will be performed exactly as it is in routine EMG tests. No serious risks are anticipated; rarely, mild pain, redness, or minor bleeding at the needle insertion site may occur. Through this study, diagnostic EMG devices could be utilized more effectively in rehabilitation and treatment monitoring. It is intended to contribute to the reduction of invasive procedures and to establish a scientific foundation for clinical applications regarding the objective evaluation of muscle activation.
Key Details
Gender
All
Age Range
20 Years - 60 Years
Study Type
INTERVENTIONAL
Enrollment
30
Start Date
2026-04-24
Completion Date
2026-07-01
Last Updated
2026-05-12
Healthy Volunteers
Yes
Interventions
Needle EMG Recording
A standard concentric needle electrode will be inserted into the M. Tibialis Anterior muscle belly. Physiological motor unit potentials will be recorded using a diagnostic EMG device to assess amplitude and duration
Adhesive Surface EMG Recording
Disposable self-adhesive surface electrodes will be placed on the skin over the motor point of the M. Tibialis Anterior. Muscle electrical activity will be recorded during voluntary contraction using a diagnostic EMG device
Ag/AgCl Cup Electrode Recording
Ag/AgCl coated cup electrodes will be attached to the skin surface of the M. Tibialis Anterior using conductive paste. Muscle signals will be captured to compare with other recording methods