Tundra Space

Tundra Space

Clinical Research Directory

Browse clinical research sites, groups, and studies.

Back to Studies
NOT YET RECRUITING
NCT07588711
NA

Transcutaneous Auricular Vagus Nerve Stimulation as a Treatment for Neuropathic Pain Following Spinal Cord Injury

Sponsor: London Health Sciences Centre Research Institute OR Lawson Research Institute of St. Joseph's

View on ClinicalTrials.gov

Summary

This pilot randomized, double-blind, sham-controlled clinical investigation will evaluate the feasibility and safety of a 30-day home-based transcutaneous auricular vagus nerve stimulation (taVNS) intervention in adults with spinal cord injury (SCI) and neuropathic pain. Participants will be randomized to receive either active taVNS targeting the auricular branch of the vagus nerve or sham taVNS delivered to the earlobe. Primary outcomes include feasibility, safety, adherence, acceptability, and blinding success. Exploratory outcomes include changes in neuropathic pain, systemic inflammatory biomarkers, vagal tone assessed via heart rate variability, and quality of life.

Official title: Transcutaneous Auricular Vagus Nerve Stimulation (taVNS) as an Anti-inflammatory Strategy for the Treatment of Neuropathic Pain Following Spinal Cord Injury

Key Details

Gender

All

Age Range

18 Years - Any

Study Type

INTERVENTIONAL

Enrollment

32

Start Date

2026-10-01

Completion Date

2028-08-30

Last Updated

2026-05-15

Healthy Volunteers

No

Interventions

DEVICE

Active Transcutaneous Auricular Vagus Nerve Stimulation

Stimulation will target the auricular branch of the vagus nerve by applying stimulation to the cymba conchae region of the ear using the tVNS R device (taVNS Technologies, Erlangen, Germany). To achieve adequate stimulation while avoiding unpleasant or painful sensations, the stimulation intensity will be gradually increased in increments of 0.1mA (milliamps) until the subjective pain threshold is reached, and then reduced to a stimulus intensity just below the individuals pain threshold (expected range based on prior studies 1 - 3.2mA). Pulse width will be set at 100μs (microseconds) and frequency will be set at 25Hz (Hertz). Parameters will be set for the duration of the intervention consisting of 4 hours of daily stimulation for a period of 30 days.

DEVICE

Sham Transcutaneous Auricular Vagus Nerve Stimulation

Stimulation will target the ear lobe using the tVNS R device (taVNS Technologies, Erlangen, Germany). To achieve adequate stimulation while avoiding unpleasant or painful sensations, the stimulation intensity will be gradually increased in increments of 0.1mA until the subjective pain threshold is reached, and then reduced to a stimulus intensity just below the individuals pain threshold (expected range based on prior studies 1 - 3.2mA). Pulse width will be set at 100μs and frequency will be set at 25Hz. Participants will perform 4 hours of stimulation per day for a period of 30 days. Stimulation will be applied to the ear lobe in order to ensure participant feel the stimulation while avoiding activation of the vagus nerve.

Locations (1)

Parkwood Institute, St Joseph's Health Care London

London, Ontario, Canada