Tundra Space

Tundra Space

Clinical Research Directory

Browse clinical research sites, groups, and studies.

Back to Studies
RECRUITING
NCT07601009

Validity and Reliability of a Mixed Reality-Based 6-Minute Walk Test

Sponsor: Selcuk University

View on ClinicalTrials.gov

Summary

The 6-Minute Walk Test (6MWT) is a widely used field test for assessing functional exercise capacity, walking endurance, and submaximal performance related to activities of daily living. However, in conventional applications, environmental conditions, observer-related differences, and standardization issues may lead to variability in measurement outcomes. In addition, evaluating only the total walking distance may not adequately reflect clinically important changes such as performance decline and walking-related motor fatigue occurring during the test. For this reason, recent studies have recommended analyzing 6MWT data by dividing the test into minute-by-minute segments and using performance change metrics such as the Distance Walked Index (DWI). These approaches allow a more detailed evaluation of changes in walking performance throughout the test duration. With advances in measurement technologies, mixed reality (MR)-based applications have attracted attention as a means of enabling more objective, standardized, and reproducible implementation of conventional clinical tests. MR technology allows users to maintain interaction with the real environment while receiving digital guidance and feedback, thereby providing a safe and standardized assessment setting. Nevertheless, evidence regarding the validity and reliability of mixed reality-based adaptations of the 6MWT, particularly in asymptomatic adults, remains limited. The aim of this study is to evaluate the criterion validity and test-retest reliability of a mixed reality-based 6-Minute Walk Test (MR-6MWT) developed using the Meta Quest 3 and Unity platform. In addition, convergent validity will be examined by analyzing the relationships between total walking distance, minute-by-minute performance changes, fatigue effect (%), and outcomes of the 4-Meter Walk Test, Timed Up and Go Test, and knee extensor muscle strength. The findings of this study are expected to contribute to the development of a more objective, standardized, and digitally based mixed reality adaptation of the 6MWT. Furthermore, the results may provide a scientific foundation for future remote assessment and digital monitoring applications.

Official title: Validity and Reliability of a Mixed Reality-Based Adaptation of the 6-Minute Walk Test in Asymptomatic Adults

Key Details

Gender

All

Age Range

18 Years - 65 Years

Study Type

OBSERVATIONAL

Enrollment

200

Start Date

2026-02-01

Completion Date

2027-01-01

Last Updated

2026-05-22

Healthy Volunteers

Yes

Interventions

OTHER

Mixed Reality-Based 6-Minute Walk Test Assessment

Participants will perform a mixed reality-based adaptation of the 6-Minute Walk Test (MR-6MWT) developed using the Meta Quest 3 headset and Unity platform. The mixed reality environment provides standardized visual guidance and virtual markers while allowing participants to safely walk in the real environment. During both conventional and MR-based assessments, walking distance, physiological responses, perceived exertion, and fatigue-related performance changes will be recorded. The MR-6MWT will be repeated one week later to evaluate test-retest reliability and compared with the conventional 6-Minute Walk Test to assess criterion validity.

Locations (1)

Selcuk University, Faculty of Health Sciences, Department of Physiotherapy and Rehabilitation

Konya, Selcuklu, Turkey (Türkiye)