Tundra Space

Tundra Space

Clinical Research Directory

Browse clinical research sites, groups, and studies.

Back to Studies
NOT YET RECRUITING
NCT07617298

EIT Evaluation of the Impact of Inhaled Nitric Oxide on Ventilation/Perfusion Mismatch in ARDS Patients Receiving Noninvasive Respiratory Support

Sponsor: Ming Zhong

View on ClinicalTrials.gov

Summary

This study aimed to quantitatively evaluate the immediate effect of inhaled nitric oxide on the ventilation / perfusion ratio in ARDS patients receiving nasal high flow oxygen therapy or noninvasive ventilation using electrical impedance tomography.

Official title: EIT Evaluation of the Impact of Inhaled Nitric Oxide on Ventilation/Perfusion Mismatch in ARDS Patients Receiving Noninvasive Respiratory Support: A Prospective Physiological Study

Key Details

Gender

All

Age Range

18 Years - 80 Years

Study Type

OBSERVATIONAL

Enrollment

40

Start Date

2026-06-30

Completion Date

2027-12-31

Last Updated

2026-06-01

Healthy Volunteers

No

Interventions

DEVICE

Inhale different doses of nitric oxide

T0 (baseline): 20 to 30 minutes after initial stabilization; T1 (iNO 5ppm 1h): The patient non invasively inhales 5ppm NO for 1h. If the reaction standard (PaO2/FiO2 improvement ≥ 20%) is met, maintain the dose until the end of the study. Otherwise, continue to double the NO concentration and proceed with the following steps:; T2 (iNO 10ppm 1h): The patient non invasively inhales 10ppm of NO for 1h. If the reaction standard is met, maintain the dose until the end of the study, otherwise continue to double the NO concentration and proceed with the following steps; T3 (iNO 20ppm 1h): The patient non invasively inhales 20ppm NO for 1h. If the reaction standard is met, maintain the dose until the end of the study, otherwise continue to double the NO concentration and proceed with the following steps; T4 (iNO 40ppm 1h): The patient non invasively inhales 40ppm NO for 1h. All subjects completed the evaluation regardless of whether they met the response criteria.

DEVICE

Inhale different doses of nitric oxide

T0 (baseline): 20 to 30 minutes after initial stabilization; T1 (iNO 5ppm 1h): The patient non invasively inhales 5ppm NO for 1h. If the reaction standard (PaO2/FiO2 improvement ≥ 20%) is met, maintain the dose until the end of the study. Otherwise, continue to double the NO concentration and proceed with the following steps:; T2 (iNO 10ppm 1h): The patient non invasively inhales 10ppm of NO for 1h. If the reaction standard is met, maintain the dose until the end of the study, otherwise continue to double the NO concentration and proceed with the following steps; T3 (iNO 20ppm 1h): The patient non invasively inhales 20ppm NO for 1h. If the reaction standard is met, maintain the dose until the end of the study, otherwise continue to double the NO concentration and proceed with the following steps; T4 (iNO 40ppm 1h): The patient non invasively inhales 40ppm NO for 1h. All subjects completed the evaluation regardless of whether they met the response criteria.

Locations (1)

Nitric Oxide Therapy Device

Shanghai, China