Clinical Research Directory
Browse clinical research sites, groups, and studies.
Air vs. Liquid: A Study on Cystoscopy Performance and Visibility Enhancement in Macrohematuria Cases
Sponsor: Kantonsspital Baden
Summary
Macroscopic haematuria is a common urological emergency. Diagnostic cystoscopy is the gold standard for identifying the bleeding source; however, blood and clots within the bladder significantly impair endoscopic visibility when saline is used as the distension medium. Air-based cystoscopy, a technique first described in the 19th century, exploits the immiscibility of gas and blood to maintain clear visualisation even during active bleeding. Despite its theoretical advantages, no randomised clinical data exist to support its use. AIROSCOPY is a prospective, randomised, controlled, single-centre superiority study comparing air-based versus saline-based flexible cystoscopy in patients with macroscopic haematuria (Grade III-V). Patients are randomised 1:1. Only the index cystoscopy (first randomised modality) contributes to all study endpoints. A second cystoscopy with the alternative modality is performed solely for patient safety to ensure no diagnostic disadvantage from study participation. This second examination is not analysed. The primary endpoint is identification of the bleeding source during the index cystoscopy (binary: yes/no). Secondary endpoints include time to source identification, total procedure duration, urologist-rated visibility (Likert scale), and patient comfort (Likert scale).
Official title: AIROSCOPY - A Prospective, Randomized, Controlled, Single-Centre Superiority Study Comparing Air-Based Versus Saline-Based Flexible Cystoscopy for the Identification of the Bleeding Source in Patients With Macroscopic Haematuria
Key Details
Gender
All
Age Range
18 Years - Any
Study Type
INTERVENTIONAL
Enrollment
40
Start Date
2026-07-01
Completion Date
2028-06-01
Last Updated
2026-06-03
Healthy Volunteers
No
Conditions
Interventions
Air-based flexible cystoscopy
Flexible cystoscopy with manual air insufflation (up to 240 ml) via bladder syringe for bladder distension and visualisation.
Saline-based flexible cystoscopy
Flexible cystoscopy with manual saline irrigation (up to 240 ml, 0.9% NaCl) via bladder syringe for bladder distension and visualisation.
Locations (1)
Kantonsspital Baden AG, Department of Urology
Baden, Canton of Aargau, Switzerland