Tundra Space

Tundra Space

Clinical Research Directory

Browse clinical research sites, groups, and studies.

Back to Studies
COMPLETED
NCT07647458
NA

Quantifying Adhesive Residue on Skin Following Removal of Maxillofacial Prosthetic Adhesives: An In Vivo Study

Sponsor: Amrita Vishwa Vidyapeetham

View on ClinicalTrials.gov

Summary

This pilot interventional in vivo study aims to quantitatively evaluate and compare the amount of adhesive residue left on the skin following removal of extraoral maxillofacial prosthetic adhesives. Five commercially available adhesives will be tested using standardized silicone strips applied to randomized sites on the forearms of healthy volunteers. After 8 hours of wear, the strips will be removed, and adhesive residue will be quantified using gravimetric analysis based on differences in strip weight before and after removal. The study also aims to evaluate adhesive failure modes and compare the cleanability of silicone-based and water-based adhesives. Findings from this study may help clinicians select adhesives that optimize prosthesis retention while minimizing skin irritation and patient burden.

Official title: A Comparative Assessment of Adhesive Residue on the Skin Following the Removal of Extraoral Silicone Prosthesis: An In Vivo Study

Key Details

Gender

All

Age Range

18 Years - 30 Years

Study Type

INTERVENTIONAL

Enrollment

5

Start Date

2024-02-20

Completion Date

2025-12-31

Last Updated

2026-06-15

Healthy Volunteers

Yes

Interventions

OTHER

Secure Adhesive Regular,

Silicone-based maxillofacial prosthetic adhesive (Factor II Inc., USA) evaluated for adhesive residue remaining on skin following removal of standardized silicone strips after 8 hours of wear.

OTHER

Secure Adhesive Extra Strength

Silicone-based maxillofacial prosthetic adhesive (Factor II Inc., USA) evaluated for adhesive residue remaining on skin following removal of standardized silicone strips after 8 hours of wear.

OTHER

Daro Adhesive Regular

Water-based maxillofacial prosthetic adhesive (Factor II Inc., USA) evaluated for adhesive residue remaining on skin following removal of standardized silicone strips after 8 hours of wear.

OTHER

Daro Adhesive Hydrobond

Water-based maxillofacial prosthetic adhesive (Factor II Inc., USA) evaluated for adhesive residue remaining on skin following removal of standardized silicone strips after 8 hours of wear.

OTHER

Pros-Aide Adhesive

Water-based maxillofacial prosthetic adhesive (ADM Tronics Inc., USA) evaluated for adhesive residue remaining on skin following removal of standardized silicone strips after 8 hours of wear.

Locations (1)

Amrita School of Dentistry, Amrita Institute of Medical Sciences, Kochi, Kerala, India

Kochi, Kerala, India