Clinical Research Directory
Browse clinical research sites, groups, and studies.
Comparison of Two Quantitative EMG Monitors for Deep Neuromuscular Block in Laparoscopic/Robotic and VATS Surgery
Sponsor: Ohio State University
Summary
The main objective of the study is to compare the frequency of intraoperative spontaneous diaphragmatic movements and breath-initiation efforts in participants undergoing robotic and/or thoracic surgery under deep neuromuscular blockade (NMB), using either the TetraGraph or TwitchView applied to the dominant hand. These events will serve as objective indicators to evaluate each device's ability to monitor and maintain adequate deep NMB.
Official title: Comparison of Two Quantitative Electromyography Monitors for Deep Neuro Muscular Block in Patients Undergoing Abdominal Laparoscopic/Robotic or Thoracic Video-Assisted (VATS) Surgeries
Key Details
Gender
All
Age Range
18 Years - Any
Study Type
INTERVENTIONAL
Enrollment
35
Start Date
2026-02-09
Completion Date
2028-08-09
Last Updated
2026-07-15
Healthy Volunteers
Yes
Conditions
Interventions
TetraGraph (Senzime)-Guided Neuromuscular Monitoring (Dominant Hand)
The TetraGraph (Senzime) quantitative electromyography (EMG) neuromuscular monitoring device will be applied to the participant's dominant hand after induction of general anesthesia and prior to neuromuscular blocking agent administration. Surface electrodes will be placed over the ulnar nerve per manufacturer instructions, and the device will be calibrated to obtain baseline Train-of-Four (TOF) measurements. Following rocuronium administration, the device will continuously monitor neuromuscular function, recording TOF approximately every 15 seconds and post-tetanic count (PTC) every 5 minutes when TOF count is zero. As the dominant-hand monitor, its readings will guide rocuronium redosing to maintain deep neuromuscular blockade (PTC 0-3) and assess recovery. During emergence, it will guide reversal, with extubation at TOF ratio ≥0.9.
TwitchView (Blink)-Guided Neuromuscular Monitoring (Dominant Hand)
The TwitchView (Blink) quantitative electromyography (EMG) neuromuscular monitoring device will be applied to the participant's dominant hand after induction of general anesthesia and prior to administration of neuromuscular blocking agents. Surface electrodes will be placed over the ulnar nerve per manufacturer instructions, and the device will be calibrated to obtain baseline Train-of-Four (TOF) measurements. Following rocuronium administration, neuromuscular function will be continuously monitored, with TOF recorded approximately every 15 seconds and post-tetanic count (PTC) every 5 minutes when TOF count is zero. As the dominant-hand device, its measurements will guide rocuronium redosing to maintain deep neuromuscular blockade (PTC 0-3) and assess recovery. During emergence, it will guide reversal, with extubation at TOF ratio ≥0.9.
Locations (1)
The Ohio State University Wexner Medical Center
Columbus, Ohio, United States