NOT YET RECRUITING
NCT07743528
NA

A Prospective, Multicenter, Two-cohorts, Single Arm Study Evaluating Safety, Effectiveness and Performance of Angimis Atherectomy System for the Treatment of Non-crossable and/or Non-dilatablE Lesions in CorONary Arteries Disease (NEON Study).

Sponsor: Shenzhen Tonglu Technology Co., Ltd

View on ClinicalTrials.gov

Summary

NEON study is a prospective, multicenter, two-cohorts, single arm study evaluating safety, effectiveness and performance of Angimis Atherectomy System for the treatment of Non-crossable and/or Non-dilatable in Coronary Arteries Disease. The primary endpoint assesses the effectiveness of the Angimis Atherectomy System by evaluating its angiographic success defined as final TIMI flow grade 3 with residual stenosis ≤30% on quantitative coronary angiography after the procedure of balloon and/or stent implementation validated by an independent, centralized core laboratory. The secondary safety endpoint assesses the rate of major complications before discharge, procedural success is defined as angiographic success without severe procedural complications (death, perforation, flow limiting dissection, acute vessel closure, or stent thrombosis) after the procedure, and clinical success defined as procedural success without complications during admission: cardiovascular death, target lesion revascularization, probable or definite stent thrombosis, stroke, and Bleeding Academic Research Consortium grade 3b or higher bleeding at 3, 6 and 12 months after the procedure. The secondary performance endpoint assesses the device technical success defined as successful preparation, delivery and use of the investigational device according to the IFU, including delivery of the laser catheter to the intended treatment location, successful delivery of laser energy, completion of the intended laser treatment without device malfunction, and retrieval of the device without device-related failure. Llaser success defined as successful lesion modification attributable to the investigational device, demonstrated by either a) successful advancement of the laser catheter across the target lesion with effective laser-mediated plaque ablation, or b) effective plaque ablation produced by laser energy delivered proximal to the lesion, enabling subsequent balloon crossing and lesion expansion that would otherwise not have been achievable.

Official title: A Prospective, Multicentre, Two-cohorts Single-arm Clinical Investigation Evaluating Safety, Effectiveness and Performance of Angimis Atherectomy System for the Treatment of Non-crossable and/or Non-dilatablE Lesions in CorONary Arteries Disease (NEON Study).

Key Details

Gender

All

Age Range

19 Years - Any

Study Type

INTERVENTIONAL

Enrollment

123

Start Date

2026-09-15

Completion Date

2028-07-15

Last Updated

2026-08-04

Healthy Volunteers

No

Interventions

DEVICE

Adult patient population who have been diagnosed with coronary artery disease with non-crossable and/or non-dilatable lesion which requiring the treatment of PCI

The device is intended for the non-crossable and/or non-dilatable lesions during PCI.