Clinical Research Directory
Browse clinical research sites, groups, and studies.
Effect of Implant Macro-Design and Surface Treatment on Insertion Torque and Early Implant Stability Quotient (ISQ)
Sponsor: Dantu implantologijos centras
Summary
This prospective, randomized pilot clinical trial will evaluate the effect of dental implant macro-design and surface treatment on insertion torque values (ITV) and early implant stability quotient (ISQ) trajectories in healed posterior mandibular bone. The study has been approved by the Vilnius University Regional Bioethics Committee (approval no. 2025/11-1722-1165) and will be conducted at a private dental clinic (Dantų implantologijos centras, Vilnius, Lithuania). Fifty implants will be randomly allocated to five groups of ten implants each, comparing two implant macro-designs - Straumann Bone Level Tapered (BLT) and Megagen BlueDiamond (BD) - combined with different surface treatments: (1) BLT with a sandblasted, large-grit, acid-etched (SLA®) surface plus chairside vacuum plasma activation (XActive®); (2) BLT with a manufacturer-hydrophilic SLActive® surface; (3) BD with a nanostructured calcium-incorporated Xpeed® surface plus chairside plasma activation; (4) BD with the standard Xpeed® surface (no plasma activation); and (5) BLT with a standard SLA surface (control, no plasma activation). Randomization will be performed by drawing a sealed envelope indicating group assignment immediately after osteotomy preparation and before implant placement. Eligible participants will be adults aged 18 years or older requiring a single dental implant in a healed mandibular molar site (at least 3 months post-extraction) suitable for a 4.1 × 10 mm implant. Insertion torque will be recorded in Newton centimeters (Ncm) using a prosthetic torque wrench at the time of implant placement. Implant stability will be measured non-invasively by resonance frequency analysis (RFA) using a SmartPeg, with ISQ recorded at four timepoints: at implant placement (baseline) and at 2, 4, and 6 weeks after placement. The primary comparisons will be (1) insertion torque according to implant macro-design (BLT vs. BD) and (2) the trajectory of ISQ change from baseline through 6 weeks according to surface treatment/plasma activation status. Correlation between insertion torque and ISQ will also be assessed. Also marginal bone maintenance (loss) will be documented from periapical radiographs obtained during prosthetic and 1 year follow-up visits. As a pilot study, this trial is designed to assess feasibility, estimate effect sizes, and inform sample-size calculations for a future, adequately powered randomized controlled trial comparing implant macro-design and surface activation strategies for early implant stability.
Official title: Effect of Implant Macro-Design and Surface Treatment on Insertion Torque and Early Implant Stability Quotient (ISQ): A Pilot Randomized Clinical Trial
Key Details
Gender
All
Age Range
18 Years - Any
Study Type
INTERVENTIONAL
Enrollment
50
Start Date
2026-07-13
Completion Date
2026-09-30
Last Updated
2026-08-04
Healthy Volunteers
Yes
Conditions
Interventions
Chairside implant surface treatment with Plasma X Motion device
XActive® chairside plasma surface activation (Plasma X Motion system) applied
SLA implant surface
Manufacturer SLA implant surface
Straumann BLT implant macro design
Straumann Bone Level Tapered implant macro design
SLActive implant surface treatment
Manufacturer SLActive surface treatment
Megagen BD implant macro design
Megagen BlueDiamond implant macro design
Megagen Xpeed implant surface treatment
Megagen Xpeed manufacturer implant surface treatment
Locations (1)
Dantu implantologijos centras
Vilnius, Lithuania