Tundra Space

Tundra Space

Clinical Research Directory

Browse clinical research sites, groups, and studies.

Back to Studies
RECRUITING
NCT07787793
NA

Effects of High-Frequency rTMS on Cortical Motor Mapping in Stroke Patients With Severe Upper Limb Impairment (MAP2024SJD)

Sponsor: Ancor Rebassa Cabrera

View on ClinicalTrials.gov

Summary

The goal of this clinical trial is to learn if a single session of high-frequency repetitive transcranial magnetic stimulation (rTMS) can increase cortical motor activity in stroke patients with severe upper limb impairment. The main question it aims to answer is: Does one session of high-frequency rTMS increase the number of motor evoked potential (MEP)-positive points in the cortical motor map of the affected hemisphere compared to sham stimulation? Researchers will compare high-frequency rTMS (10 Hz, 600 pulses) applied over the affected motor cortex to sham stimulation to see if rTMS increases detectable cortical motor responses in patients who have little or no voluntary hand movement after stroke. Participants will: Undergo a cortical motor mapping assessment before the intervention. Receive either one session of real rTMS or sham stimulation, depending on their randomly assigned group. Undergo a second cortical motor mapping assessment immediately after the intervention.

Official title: Effects of a Single Session of High-Frequency Repetitive Transcranial Magnetic Stimulation on Cortical Mapping of the Upper Limb in Stroke Patients With Severe Upper Limb Impairment

Key Details

Gender

All

Age Range

18 Years - Any

Study Type

INTERVENTIONAL

Enrollment

54

Start Date

2026-09-15

Completion Date

2026-12

Last Updated

2026-08-26

Healthy Volunteers

No

Interventions

DEVICE

High-frequency repetitive transcranial magnetic stimulation

Single session of 10 Hz rTMS using a Magstim Rapid2 stimulator with a D70mm Air Film figure-of-eight coil. Parameters: 600 pulses in trains of 15 pulses (1.5 s on, 10 s off) at 80% of the motor threshold over the optimal hotspot of the affected hemisphere (or C3/C4 if no MEP-positive point is identified). Parameters are within IFCN safety guidelines.

DEVICE

Sham transcranial magnetic stimulation

Same coil (Magstim Rapid2 / D70mm Air Film) placed at the same position as the active condition but rotated 90 degrees, producing comparable auditory and cutaneous sensations without effective cortical stimulation.

Locations (1)

Hospital Sant Joan de Déu Palma

Palma, Balearic Islands, Spain