Tundra Space

Tundra Space

Clinical Research Directory

Browse clinical research sites, groups, and studies.

Back to Studies
COMPLETED
NCT07866976
NA

Effects of Power Arm Application in Maxillary Canine Distalization

Sponsor: Atlas University

View on ClinicalTrials.gov

Summary

The aim of this study is to investigate the effects of a canine distalization force applied between power arms placed on the maxillary canine and first molar, in comparison with the classical method without power arms. Following maxillary first premolar extraction, canine distalization is commonly accompanied by undesirable effects such as distal tipping and distopalatal rotation of the canine and mesial movement (anchorage loss) of the first molar. By bringing the applied force closer to the teeth's centers of resistance through power arms, the study seeks to move the canine into the extraction space as close to parallel (bodily) movement as possible. The hypothesis is that applying force with Ni-Ti closed-coil springs between power arms placed on the molar and canine teeth reduces undesirable dental effects such as rotation, tipping and anchorage loss during distalization compared with the classical method. In a split-mouth design, 16 patients with maxillary first premolar extractions and moderate anchorage requirement receive power-arm mechanics on one randomly selected side (study side) and conventional mechanics on the other side (control side), with a 150 g force on both sides, over three months of canine distalization.

Official title: Investigation of the Effects of Power Arm Application in Canine Distalization: A Randomized Split-Mouth Clinical Trial

Key Details

Gender

All

Age Range

14 Years - 20 Years

Study Type

INTERVENTIONAL

Enrollment

16

Start Date

2024-01-22

Completion Date

2025-03-01

Last Updated

2026-10-09

Healthy Volunteers

No

Interventions

DEVICE

Canine and molar power arms

Molar tube with a power arm and a U-shaped canine power arm bent from 0.016 x 0.022-inch stainless steel wire (gingival opening facing mesially), adjusted to the molar power-arm height; a 9-mm Ni-Ti closed-coil spring is attached between the two power-arm hooks via a 0.010-inch long ligature wire and activated to 150 g measured with a force gauge.

PROCEDURE

Conventional canine retraction

9-mm Ni-Ti closed-coil spring delivering 150 g attached directly between the molar tube hook and the canine bracket hook.

Locations (1)

Ondokuz Mayıs University, Faculty of Dentistry, Department of Orthodontics

Samsun, Turkey (Türkiye)