Clinical Research Directory
Browse clinical research sites, groups, and studies.
Effectiveness of Sequential Monopolar and Bipolar Radiofrequency Device for Facial Rejuvenation in Female Participants
Sponsor: Cutis Medical Laser Clinics Pte Ltd
Summary
The purpose of this study is to find out whether a single treatment with the DENSITY radiofrequency device improves facial skin laxity (sagging), skin texture, and pore appearance in adult women, and whether the treatment is safe and well tolerated. The DENSITY device delivers radiofrequency energy to the skin in two modes, one after the other: monopolar mode, which heats deeper layers of the skin, and bipolar mode, which heats more superficial layers. Heating the skin in this controlled way is intended to stimulate the body to produce new collagen, which may firm and smooth the skin over time. Women aged 25 to 60 with mild to moderate facial skin laxity receive one treatment session to the face and neck at the first visit. They return for follow-up visits about 30 days and 90 days after treatment. At each visit, researchers take standardized three-dimensional (3D) facial images, grade skin laxity and overall aesthetic improvement, and ask participants to complete questionnaires about how satisfied they are with their face and skin. Side effects such as redness, swelling, or discomfort are recorded throughout the study. The main questions this study aims to answer are: * Does one DENSITY treatment improve skin texture, pore appearance, and facial contour, as measured by 3D imaging? * Do participants report greater satisfaction with their facial appearance and skin after treatment? * Is the treatment safe and well tolerated?
Key Details
Gender
FEMALE
Age Range
25 Years - 60 Years
Study Type
INTERVENTIONAL
Enrollment
14
Start Date
2026-01-01
Completion Date
2026-09-30
Last Updated
2026-11-12
Healthy Volunteers
No
Conditions
Interventions
DENSITY sequential monopolar and bipolar radiofrequency device
Single treatment session to the face and neck using the DENSITY radiofrequency system (Jeisys Medical Inc.), operating at 6.78 MHz and delivering monopolar and bipolar radiofrequency energy sequentially with Classic-F and High-F tips. Monopolar mode targets deeper tissue with a neutral grounding electrode in place; bipolar mode targets more superficial dermis. Energy setting approximately 3.0 to 3.5, two passes, approximately 300 shots, with a treatment endpoint of uniform mild erythema and a comfortable warming sensation. Topical anesthetic applied where required.
Locations (1)
Cutis Medical Laser Clinics Pte Ltd
Singapore, Singapore