Clinical Research Directory
Browse clinical research sites, groups, and studies.
A Clinical Study to Collect Real-wordt Data on Safety and Clinical Performance of the VCFix Spinal System for Treatment of Vertebral Compression Fractures of (Suspected) Osteoporotic Origin.
Sponsor: Amber Implants B.V.
Summary
This study is designed as a prospective, post-market, multi-center, single-arm study to collect real-world data of the VCFix Spinal System used in US clinical practice. Approximately 5 centers in the US will enroll subjects with VCF in a non-randomized fashion, and VCFix will be used within its cleared purpose and indications for use. The study has been designed to be methodologically compatible with the EU EXPAND (CIP-VS02-EU) study, thereby aiming for the pooling of data to the EU study. Data pooling will be pursued only as a sensitivity analysis if pre-specified similarity criteria are met. The US study provides meaningful real-world evidence regardless of pooling feasibility. The targeted patient population, assessment schedule, and study endpoints are therefore similar to those of the EU EXPAND study.
Official title: A Prospective, Multicenter, Post-Market Clinical Study Collecting Real-World Data of the VCFix Spinal System in Stand-Alone Configuration for Vertebral Augmentation (EXPAND-US)
Key Details
Gender
All
Age Range
21 Years - 85 Years
Study Type
OBSERVATIONAL
Enrollment
30
Start Date
2026-10-04
Completion Date
2028-12-31
Last Updated
2026-11-05
Healthy Volunteers
No
Conditions
Interventions
VCFix Spinal System in stand-alone configuration
The distinguishing features of this inetrvention reside in: 1. In situ adjustment and maintenance of the height and angle of the device that allows expansion of the fractured VB in the cranio-caudal direction to realign the vertebral endplates and correct kyphosis. 2. The complex titanium perforated structure with optimized surface roughness that allows possible bone attachment, thereby permitting natural healing of the bone and potentially providing more stability to the device and the treated vertebra over time. 3. The ability to connect the posterior to the anterior column of the spine through the pedicle screw component of the VCFix implant, therefore improving the biomechanical load distribution and consequently the ability to stabilize more severe fractures.
Locations (3)
Montefiore Medical Center
New York, New York, United States
University of Oklahoma Health Campus
Oklahoma City, Oklahoma, United States
Rothman Orthopaedics
Philadelphia, Pennsylvania, United States