NOT YET RECRUITING
NCT07929467
NA

Leadless Versus Conventional Pacemakers: Effects on Heart Function and Heart Failure

Sponsor: Karl Landsteiner University of Health Sciences

View on ClinicalTrials.gov

Summary

People with a slow heart rhythm may need a permanent pacemaker. Conventional pacemakers use a device placed under the skin and wires that pass through veins into the heart. Leadless pacemakers are placed directly inside the heart without a chest pocket or these wires. Both approaches can provide pacing, but their effects on heart function and heart-failure-related problems need to be compared. LEAP-HF will compare an indication-adapted leadless pacemaker strategy with a conventional transvenous pacemaker strategy in 760 adults for whom either approach is clinically appropriate. Participants must have a left ventricular ejection fraction above 40% and must not require a defibrillator, cardiac resynchronization therapy, or chronic atrial pacing. Participants will be assigned by chance, in equal proportions, to the two strategies. The device and pacing mode will be selected according to the participant's clinical indication within the assigned strategy. The main question is whether the leadless strategy is not unacceptably worse than the conventional strategy for pacing-induced cardiac dysfunction during 12 months of follow-up. This outcome includes a qualifying deterioration in heart pumping function, pacemaker syndrome, heart failure requiring hospitalization, or an upgrade to cardiac resynchronization therapy. The prespecified non-inferiority margin is an absolute difference of 7 percentage points. Assessments include heart ultrasound, pacemaker checks, an electrocardiogram, a blood test for NT-proBNP, symptom assessment, and questionnaires about health and quality of life. There will be a telephone contact at 6 weeks and in-person visits at 6 and 12 months after implantation. The study will also compare heart function, complications, further procedures, and deaths. Participants and treating teams will know which pacing system was implanted; selected clinical events will be reviewed by an independent committee unaware of the assigned treatment.

Official title: Leadless Pacing and Heart Failure: A Prospective, Randomized, Open-Label, Non-Inferiority Trial

Key Details

Gender

All

Age Range

18 Years - Any

Study Type

INTERVENTIONAL

Enrollment

760

Start Date

2027-11

Completion Date

2029-12

Last Updated

2026-11-10

Healthy Volunteers

No

Interventions

DEVICE

Leadless pacemaker implantation

Implantation and indication-adapted programming of a leadless pacemaker system. The current protocol lists Medtronic Micra VR2, Medtronic Micra AV2, Abbott AVEIR VR, and Abbott AVEIR AR/VR dual-chamber systems. The selected system must be appropriate for the clinical indication and permitted by the applicable approvals and study protocol. Follow-up includes standardized device interrogation and assessment of ventricular pacing burden.

DEVICE

Conventional transvenous pacemaker implantation

Implantation and indication-adapted programming of a conventional transvenous single- or dual-chamber pacemaker with right ventricular pacing. The current protocol lists systems from Abbott, Biotronik, Boston Scientific, Medtronic, and MicroPort/Sorin. Device type and pacing mode are selected according to the prespecified clinical algorithm. Lead position, electrical parameters, programming, and right ventricular pacing burden are documented. Conduction system pacing is not part of the assigned strategy.

Locations (1)

University Hospital St. Pölten, Department of Internal Medicine 3 - Cardiology

Sankt Pölten, Lower Austria, Austria