Tundra Space

Tundra Space

Clinical Research Directory

Browse clinical research sites, groups, and studies.

Back to Studies
RECRUITING
NCT07943702

Correlation Between Visual Reading and DOlab Software Quantitative Analysis of DaT-SPECT Images

Sponsor: Dorian Technologies S.r.l.

View on ClinicalTrials.gov

Summary

The goal of this study is to find out whether the quantitative results of DOlab software (DaT-SPECT workflow) agree with the visual reading of brain scans performed by nuclear medicine physicians. The scans are 123I-ioflupane DaT-SPECT images of adults who were evaluated for dopamine transporter dysfunction, a condition seen in Parkinson's disease, other parkinsonian syndromes and dementia with Lewy bodies. The main questions it aims to answer are: * Do the visual scores given by expert readers (0 = normal to 3 = marked abnormality) correlate with the values calculated by the software? * Does using the software report change or refine the readers' classification compared with visual reading alone? * How usable do readers find the software? The study uses existing scans of 120 patients collected between January 2015 and May 2025 at two Italian hospitals. No new tests or treatments are given to participants, and the software results are not used for their clinical care.

Official title: Pre-market Clinical Investigation to Evaluate the Correlation Between Visual Interpretation and Quantitative Analysis Performed by DOlab Software - DaT-SPECT Workflow for the Identification of Neurological Disorders Related to Dopamine Transporter Dysfunction

Key Details

Gender

All

Age Range

18 Years - Any

Study Type

OBSERVATIONAL

Enrollment

120

Start Date

2026-10-13

Completion Date

2027-03

Last Updated

2026-11-17

Healthy Volunteers

No

Interventions

DEVICE

DOlab software - DaT-SPECT workflow

Investigational software (not CE-marked, class IIa) that automatically quantifies striatal 123I-ioflupane binding using four metrics (SBR, Southampton SBR, Basal Ganglia V3, Volume Fraction) and compares them with a PPMI-based normative database. It is applied retrospectively to existing images, and its output is not used for patient care.

DIAGNOSTIC_TEST

Visual interpretation (comparator)

Visual reading of the same 123I-ioflupane images by blinded nuclear medicine physicians, scored 0-3 for the caudate, anterior putamen and posterior putamen of each hemisphere, according to the EANM/SNMMI guidelines.

Locations (2)

Azienda USL Toscana Centro - Ospedale Santo Stefano

Prato, Tuscany, Italy

Azienda Ospedale Università Padova

Padova, Veneto, Italy