HA380 Hemoadsorption Combined With Continuous Renal Replacement Therapy Versus Continuous Renal Replacement Therapy Alone in Septic Shock

Sponsor: The 108 Military Central Hospital

View on ClinicalTrials.gov

Summary

The goal of this clinical trial is to learn whether adding an HA380 hemoadsorption cartridge to continuous renal replacement therapy (CRRT) helps adults with septic shock and acute kidney injury requiring CRRT recover from shock better than CRRT alone. Septic shock is a life-threatening condition in which an infection triggers an excessive inflammatory response, causing very low blood pressure and organ failure. The HA380 cartridge is a device placed in the CRRT blood circuit that is designed to remove inflammatory molecules (cytokines) from the blood. The main question it aims to answer is: Does CRRT combined with the HA380 cartridge result in a lower blood lactate level (a marker of poor oxygen delivery to the body's tissues) at 24 hours than CRRT alone? Researchers will also compare the two groups in terms of the amount of blood-pressure-supporting medicines needed, blood levels of inflammatory cytokines, organ function, time to recovery from shock, need for organ support, length of intensive care unit (ICU) and hospital stay, survival up to 28 days, and side effects. Participants will: * Be randomly assigned to receive either CRRT combined with the HA380 cartridge or CRRT alone, in addition to the same standard septic shock care * If assigned to the HA380 group, receive three HA380 cartridges consecutively, each for 6 hours (18 hours in total), followed by CRRT alone as needed * Have their vital signs, medicine doses and blood tests recorded before treatment and at set times up to day 7 * Be followed up for survival and recovery until day 28

Official title: Efficacy of Continuous Renal Replacement Therapy Combined With the HA380 Hemoadsorption Cartridge Versus Continuous Renal Replacement Therapy Alone in the Treatment of Septic Shock: A Single-Center, Open-Label, Assessor-Blinded, Randomized Controlled Trial

Key Details

Gender

All

Age Range

18 Years - Any

Study Type

INTERVENTIONAL

Enrollment

70

Start Date

2026-11

Completion Date

2028-11

Last Updated

2026-11-20

Healthy Volunteers

No

Interventions

DEVICE

HA380 Hemoadsorption Cartridge

Single-use neutral macroporous resin hemoadsorption cartridge (Jafron Biomedical), primed with heparinized saline according to the manufacturer's instructions and connected in series after the M100 hemofilter, before blood returns to the patient. Three cartridges are used consecutively, each for 6 hours (total 18 hours), starting with the first CRRT session

PROCEDURE

Continuous Renal Replacement Therapy

Continuous venovenous hemodiafiltration (CVVHDF) on the Prismaflex system with an M100 hemofilter (maximum 24 hours per filter), blood flow 150-200 mL/min, effluent dose 25-30 mL/kg/h, lactate-free bicarbonate-buffered solutions, unfractionated heparin anticoagulation per protocol (no anticoagulation if platelet count \<50 ×10⁹/L); started within 2 hours of randomization.

Locations (1)

The 108 Military Central Hospital

Hanoi, Vietnam