Tundra Space

Tundra Space

Clinical Research Directory

Browse clinical research sites, groups, and studies.

Back to Studies
NOT YET RECRUITING
NCT07957378
NA

Slow Up, Slow Down, and Wait Balloon Inflation Before Planned Drug-Coated Balloon Treatment in Patients With Coronary Artery Disease

Sponsor: China National Center for Cardiovascular Diseases

View on ClinicalTrials.gov

Summary

The SSW-DCB study will test whether a slow balloon inflation technique reduces the need for a stent during a coronary procedure in adults with coronary artery disease who are scheduled for drug-coated balloon treatment. Before using a drug-coated balloon, doctors use a separate balloon to prepare the narrowed area of the artery. Participants will be assigned by chance to one of two groups, with an equal chance of joining either group. In one group, doctors will use the Slow Up, Slow Down, and Wait (SSW) technique, which involves gradually increasing the balloon pressure, holding it briefly, and then gradually releasing the pressure. In the other group, doctors will use the usual balloon inflation technique. After preparing the artery, doctors will check whether it is suitable for treatment with a drug-coated balloon. If the artery meets the study criteria for needing a stent, a stent may be placed during the procedure. This is called bailout stenting. The main question is whether fewer participants in the SSW group need bailout stenting. Follow-up visits or calls are planned at 1, 6, 9, and 12 months after the procedure. A repeat coronary angiogram is planned at 12 months to check the treated area. Longer-term follow-up will collect information about heart-related and bleeding events.

Official title: Slow Up, Slow Down, and Wait Strategy for Drug-Coated Balloon Treatment: A Randomized Controlled Trial of Slow Versus Routine Balloon Inflation During Preparation of De Novo Coronary Lesions to Reduce Intraprocedural Bailout Stenting

Key Details

Gender

All

Age Range

18 Years - Any

Study Type

INTERVENTIONAL

Enrollment

718

Start Date

2026-12-01

Completion Date

2029-09-30

Last Updated

2026-11-24

Healthy Volunteers

No

Interventions

PROCEDURE

Slow Up, Slow Down, and Wait Balloon Inflation

During coronary lesion preparation, the operator initially inflates the balloon to unfold it, then increases pressure at 2 atmospheres per second to the target pressure. The operator holds the target pressure for 5 to 10 seconds and then releases pressure at no more than 2 atmospheres per second until it reaches zero.

PROCEDURE

Routine Balloon Inflation

During coronary lesion preparation, the operator increases balloon pressure rapidly and continuously to the target pressure over 3 to 5 seconds, holds the target pressure for 5 to 10 seconds, and then deflates the balloon by applying negative pressure with the inflation device.

Locations (1)

Fuwai Hospital, Chinese Academy of Medical Sciences and Peking Union Medical College

Beijing, Beijing Municipality, China