Tundra Space

Tundra Space

Clinical Research Directory

Browse clinical research sites, groups, and studies.

Back to Studies
COMPLETED
NCT07957703
NA

Comparison of Mean Pressure Reduction in Endotracheal Tube (ETT) Cuff Pressure Monitoring at 8-Hourly Versus 12-Hourly Intervals in Surgical ICU Patients: Effects on Ventilator Associated Pneumonia (VAP).

Sponsor: Universiti Sains Malaysia

View on ClinicalTrials.gov

Summary

The goal of this clinical trial is to learn whether checking the breathing tube (endotracheal tube) cuff pressure every 12 hours works as well as checking it every 8 hours in adults on a ventilator in the surgical intensive care unit. Keeping cuff pressure between 20 and 30 cmH₂O helps prevent injury to the windpipe and stops secretions leaking into the lungs, which can cause ventilator-associated pneumonia (VAP). The main questions it aims to answer are: * Does cuff pressure drop more over 7 days when it is checked every 12 hours rather than every 8 hours? * Is there a difference in how many patients develop VAP or lung collapse (atelectasis) on ultrasound within 7 days? Researchers will also look at whether head position, body position and tracheal suctioning are linked to drops in cuff pressure. Participants will be adults in the surgical ICU at Hospital Pakar Universiti Sains Malaysia who are expected to need a ventilator for at least 48 hours. They will be randomly assigned to cuff-pressure checks every 8 hours or every 12 hours. At each check, the pressure is measured with a manometer and reset to 25 cmH₂O if it is outside 20-30 cmH₂O. Patients will be followed for up to 7 days.

Key Details

Gender

All

Age Range

18 Years - 70 Years

Study Type

INTERVENTIONAL

Enrollment

128

Start Date

2024-06-01

Completion Date

2026-05-31

Last Updated

2026-11-24

Healthy Volunteers

No

Interventions

BEHAVIORAL

8-hourly cuff pressure monitoring

Trained staff nurses measure ETT cuff pressure with a VBM manometer every 8 hours, following a standardised protocol. Pressures outside 20 to 30 cmH2O are corrected to 25 cmH2O, and the adjustment is recorded. Head position, body position and ETT suctioning are recorded at each measurement.

BEHAVIORAL

12-hourly cuff pressure monitoring

Trained staff nurses measure ETT cuff pressure with a VBM manometer every 12 hours, following a standardised protocol. Pressures outside 20 to 30 cmH2O are corrected to 25 cmH2O, and the adjustment is recorded. Head position, body position and ETT suctioning are recorded at each measurement.

Locations (1)

Surgical Intensive care Unit

Kubang Kerian, Kelantan, Malaysia