Clinical Research Directory
Browse clinical research sites, groups, and studies.
3D Video to Measure Breathing and Breathing-Muscle Activity
Sponsor: EssaiClinique_KINEVENT
Summary
Doctors often need to know how well a patient is breathing. Two things matter: how much air a person moves with each breath, and how hard the breathing muscles are working. Today, measuring these usually requires devices placed on or inside the body, which can be uncomfortable and are not always suitable at the bedside. This study tests a new way to measure breathing without touching the body. A set of cameras films the surface of the chest and neck and builds a three-dimensional image of how they move during breathing. A computer uses these movements to estimate the amount of air breathed and to detect when the breathing muscles are being used. The purpose of this study is to check whether the camera-based method is accurate. To do this, the researchers compare it with standard breathing measurements in healthy adult volunteers. During a single session, volunteers breathe normally and then breathe against increasing resistance, which makes breathing a little harder, while the cameras and the standard devices record at the same time. The study will include 10 healthy volunteers (5 women and 5 men). It does not involve any treatment, and no results are expected to directly benefit the participants. If the method proves accurate, it could later be tested in patients to help monitor breathing in intensive care.
Official title: Non-invasive Measurement of Tidal Volume and Inspiratory Muscle Recruitment Using Three-dimensional Video in Healthy Volunteers Under Incremental Inspiratory Loading: a Pilot Agreement Study
Key Details
Gender
All
Age Range
18 Years - Any
Study Type
INTERVENTIONAL
Enrollment
10
Start Date
2026-12-01
Completion Date
2027-12-01
Last Updated
2026-11-24
Healthy Volunteers
Yes
Conditions
Interventions
Three-dimensional markerless video system for respiratory surface motion analysis
A markerless multi-camera system reconstructs the three-dimensional surface of the torso without contact or skin markers. Surface deformations over the respiratory cycle are used to estimate tidal volume and to derive regional indices of respiratory muscle recruitment (cervical region and lower thoraco-abdominal region). During a single session, recordings are acquired simultaneously with a calibrated spirometer (reference tidal volume) and with surface electromyography of the sternocleidomastoid and of the diaphragmatic zone of apposition. The video system is calibrated beforehand on a bench using an artificial lung delivering known volumes. The device is used for measurement only, is non-invasive, and emits no radiation.