Clinical Research Directory
Browse clinical research sites, groups, and studies.
3 clinical studies listed.
Filters:
Tundra lists 3 Biosensing Techniques clinical trials. Each listing includes eligibility criteria, study locations, and direct links to research sites in the Tundra directory.
This data is also available as a public JSON API. AI systems and LLMs are encouraged to use it for structured queries.
NCT05297266
Early Discovery of Ischemia After Replantation Surgery of the Extremities
Investigators will test if changes in CO2 is detected postoperatively in ischemic tissue in a replanted extremity of a traumatically amputated upper or lower extremity. IscAlert is measuring continuously CO2 in muscular and subcutaneous tissue. IscAlert is inserted distal to the operative field into normal muscle and/or subcutaneous tissue in the replanted extremity. Local tissue CO2 and temperature will be monitored continuously postoperatively for the next 10 days. If a reduced or totally obstructed blood flow appear (thrombosis), an increase in tissue CO2 and a lower local temperature will emerge rapidly as a sign of ischemia. This will be detected by the sensor which will alarm the investigators. This will lead to assessment of the replanted extremity and if restricted blood flow is diagnosed, a reoperation will be performed. After reoperation new sensors will be implanted for another ten days if applicable. Sixty patients will be enrolled to undergo the procedures. The IscAlert will be removed from the patient before the patient is discharged from the hospital or a maximum of 10 days (the event that occurs first). 500 devices is planned to be used in this clinical study.
Gender: All
Ages: 18 Years - 100 Years
Updated: 2025-03-25
NCT06079255
Ischemia Detection During Development of Acute Compartment Syndrome
This is an open, observational, prospective, descriptive, single-centre study including 60 patients. The study is designed to investigate if IscAlert sensor system can be used for reliable and continuous tissue carbon dioxide (pCO2)- and temperature monitoring in muscular tissue in lower extremity in patients at risk of developing acute compartment syndrome.
Gender: All
Ages: 18 Years - 110 Years
Updated: 2025-03-25
NCT05487820
Detecting Tissue Ischemia in Reconstruction Flaps by a Novel CO2 Biosensor (DIMENSION-study)
The investigators will test if changes in CO2 is detected postoperatively in ischemic tissue in a reconstructed flap. IscAlert is measuring continuously CO2 in muscular and subcutaneous tissue. IscAlert is inserted distal to the operative field into normal muscle and/or subcutaneous tissue in the reconstructed flap. Local tissue CO2 and temperature will be monitored continuously postoperatively until maximal 10 days. If a reduced or totally obstructed blood flow appear (thrombosis), an increase in tissue CO2 and a lower local temperature will emerge rapidly as a sign of ischemia. This will be detected by the sensor which will alarm the investigators. This will lead to assessment of the reconstructed flap and if restricted blood flow is diagnosed, a reoperation or other intervention will be performed. 56 patients will be enrolled to undergo the procedures. The IscAlert will be removed from the patient before the patient is discharged from the hospital or a maximum of 10 days (the event that occurs first). 360 devices are planned to be used in this clinical study.
Gender: All
Ages: 18 Years - Any
Updated: 2025-03-25