Clinical Research Directory
Browse clinical research sites, groups, and studies.
5 clinical studies listed.
Filters:
Tundra lists 5 Defibrillators, Implantable clinical trials. Each listing includes eligibility criteria, study locations, and direct links to research sites in the Tundra directory.
This data is also available as a public JSON API. AI systems and LLMs are encouraged to use it for structured queries.
NCT07332871
Conduction System Pacing and AV Junction Ablation in Heart Failure With Atrial Fibrillation (SYNC AF-HTx)
The purpose of this study is to evaluate the safety and efficacy of conduction system pacing (CSP) using left bundle branch pacing (LBBP) and atrioventricular junction (AVJ) ablation in patients with end-stage heart failure and permanent atrial fibrillation (AF). Participants who are candidates for heart transplantation or left ventricular assist device (LVAD) implantation will be randomized to either the SYNC group (ICD implantation combined with LBBP and AVJ ablation) or the control group (ICD implantation only). The investigators will compare clinical outcomes, including mortality and heart failure hospitalization, between the two strategies over a 1-year follow-up period.
Gender: All
Ages: 19 Years - Any
Updated: 2026-01-12
NCT06330675
Correct Mobilization Time After Implantation of an Intracardiac Electronic Device Implantation
Bedrest is usually prescribed for patients management after cardiac electronic device implantation (CIED) in order to prevent complication. Due to the lack of guidelines available on the timing of postoperative mobilization management, the aim of the study is to evaluate the safety of early mobilization, comparing mobilization at 4-h against day-after procedure.
Gender: All
Ages: 18 Years - Any
Updated: 2025-08-13
NCT06842940
Slew Rate As a Predictor for Optimal Lead Fixation
The goal of this observational study is to identify the most reliable electrical parameter measured at the time of implantation that can predict optimal lead fixation and long-term lead performance in patients undergoing transvenous pacemaker or implantable cardioverter-defibrillator (ICD) implant. The main questions it aims to answer are: * Is there a correlation between the slew rate measured at the time of lead implantation and the sensing measured at the 12-month follow-up? * Is there a correlation between all electrical parameters recorded at implantation (including slew rate, current of injury, acute sensing, acute impedance, and acute pacing threshold) and the electrical parameters assessed at 12 months post-implantation (specifically chronic sensing, chronic impedance, and chronic pacing threshold)? Participants will undergo regular follow-up evaluations, with device interrogation visits scheduled at 1 and 12 months post-implantation as part of routine clinical care.
Gender: All
Ages: 18 Years - 100 Years
Updated: 2025-02-24
NCT06739239
French COhoRte Extra-Vascular Implantable CardiovErter DefibrillatoR
Implantable cardioverter-defibrillators (ICDs) are widely recognized for their efficacy in reducing the risk of sudden cardiac death in high-risk patients. Nonetheless, there remains significant scope for improving outcomes through advancements in device technology and design. The extravascular cardioverter-defibrillator (EV-ICD) represents such an innovation, offering key advantages over other ICD systems. It incorporates a lead positioned in the substernal space, enabling the delivery of pause-prevention security pacing, antitachycardia pacing, and defibrillation energy similar to that provided by conventional transvenous ICDs. Previous studies have demonstrated that EV-ICDs can be implanted safely and are capable of terminating majority of induced ventricular arrhythmias during implantation; however, follow-up data are limited to highly experienced selected centers and over a relatively small follow-up period (6-month follow-up). The FOREVER cohort study, initiated by the French Institute of Health and Medical Research, aims to evaluate the EV-ICD use in France. This nationwide evaluation will provide an exhaustive collection of all EV-ICD implantations in France, offering valuable real-world evidence on the long-term safety and efficacy of the device.
Gender: All
Updated: 2024-12-20
NCT06597578
Prospective Köln Bonn Registry for the Extraction of Pacmaker and ICD Leads
The KOBES registry is an all-comers prospective clinical registry of the cooperative Köln Bonn lead extraction center. All patients undergoing complex lead extraction procedures (i.e. indwelling leads \> 6months) in the hybrid operating room with cardiothoracic standby will be included in the registry. Preoperative, intraoperative/procedural and postoperative parameters will be recorded. All patients will be asked to provide written informed consent. Data will be pseudonomyzed and entered into a data sheet. Data will be monitored by a board and evaluated independently.
Gender: All
Ages: 18 Years - Any
Updated: 2024-09-19