Tundra Space

Tundra Space

Clinical Research Directory

Browse clinical research sites, groups, and studies.

6 clinical studies listed.

Filters:

Intramural Hematoma

Tundra lists 6 Intramural Hematoma clinical trials. Each listing includes eligibility criteria, study locations, and direct links to research sites in the Tundra directory.

This data is also available as a public JSON API. AI systems and LLMs are encouraged to use it for structured queries.

ACTIVE NOT RECRUITING

NCT03894033

Post-market Registry of the AMDS for the Treatment of Acute DeBakey Type I Dissection

The objective of this registry is to collect information on the performance and clinical benefits of the AMDS (Ascyrus Medical Dissection Stent) to treat patients with acute "DeBakey type I dissections" and with or without so called "preoperative clinically relevant malperfusion" and/or "intramural hematomas". In a healthy aorta (the vessel that supplies blood to most of the body) the blood flows freely through the main lumen (a space inside the vessel where blood flows). The participants involved in this study have a tear that has separated the inner layer of the aorta wall and created a secondary channel (false lumen) in addition to the main channel (true lumen), and huts, the blood flows through both channels. AMDS is a stent (a metal tube helping to keep the vessel open) that is placed in the descending thoracic aorta. AMDS is a medical device commercially available in the countries in which the study is being conducted and it is used as standard of care according to its indication.

Gender: All

Ages: 18 Years - 80 Years

Updated: 2026-02-09

1 state

Aortic Dissection
Acute DeBakey I Dissection
Acute Type A Dissection
+1
RECRUITING

NCT06658730

Long-term Characterization of GORE® TAG® Conformable Thoracic Stent Graft With ACTIVE CONTROL System Performance

An observational, prospective multi-regional post-market registry collecting mid- and long-term data to assess outcomes through ten years of follow-up for subjects treated with GORE® TAG® Conformable Thoracic Stent Graft with ACTIVE CONTROL System as a part of routine clinical practice. This post-market registry for the GORE® TAG® Conformable Thoracic Stent Graft with ACTIVE CONTROL System (CTAG w/AC) is intended to demonstrate that thoracic endovascular aortic repair (TEVAR) for lesions of the descending thoracic aorta continues to be a suitable treatment option for appropriately selected patients.

Gender: All

Ages: 18 Years - Any

Updated: 2026-01-21

3 states

Vascular Disease
Dissection
Dissection Aortic Aneurysm
+5
RECRUITING

NCT04471909

NEXUS Aortic Arch Clinical Study to Evaluate Safety and Effectiveness

Prospective, non-randomized, multi-center clinical investigation of the NEXUS™ Aortic Arch Stent Graft System (NEXUSTM) for the treatment of thoracic aortic lesions involving the aortic arch with a proximal landing zone, native or previously implanted surgical graft, in the ascending aorta and with a brachiocephalic trunk native landing zone.

Gender: All

Ages: 18 Years - Any

Updated: 2025-10-20

23 states

Aortic Dissection
Aortic Aneurysm
Intramural Hematoma
+1
RECRUITING

NCT02201589

Feasibility of Endovascular Repair Of Ascending Aortic Pathologies

The purpose of this study is to investigate the outcome of patients with pathologies of the ascending thoracic aorta (diseases in the great blood vessel or artery that leads away from the heart) including type A aortic dissection, retrograde type A aortic dissection, intramural hematoma, penetrating ulcer or pseudoaneurysm who are suitable for endovascular (within the vessel) repair with the Medtronic Valiant PS-IDE (Physician Sponsored-Investigational Device Exemption) Stent Graft. Type A aortic dissection is a condition where blood passes through the inner lining or between the layers of the blood vessel from a tear in the aortic wall (dissection) in the ascending aorta; a retrograde Type A aortic dissection is a condition where the dissection or tear in the ascending aorta starts from the descending aorta; an intramural hematoma is a collection of clotted blood within the aortic wall; a penetrating ulcer has a plaque or clot within the wall and a pseudoaneurysm is a false aneurysm . If left untreated in any of these conditions, the aorta can enlarge and rupture causing injury or death. The plan for these patients is to repair the ascending thoracic aorta using the Medtronic Valiant PS-IDE Stent Graft with the Captivia Delivery System. The Valiant Captivia has been evaluated worldwide and used extensively in patients with type B (descending) thoracic aortic dissection. Since the dissections in the ascending aortas mirror that of the descending aorta, it is expected that this stent graft will deliver similar performance and endurance in patients with type A aortic dissection. The investigators expect to reroute the blood to the true lumen (the inner space within the blood vessel) by covering the proximal (nearest to the heart) tear with the stent graft. The stent graft is a stent frame made from Nitinol wire and covered with an expandable material made of a polyester material. This new study will determine how well the device works to treat dissections, intramural hematomas, penetrating ulcers and pseudoaneurysms in the ascending thoracic aorta.

Gender: All

Ages: 18 Years - Any

Updated: 2025-05-06

1 state

Aortic Dissection
Intramural Hematoma
Penetrating Ulcer
+1
RECRUITING

NCT05874206

CRATOS - Evaluation of Cratos™ Branch Stent Graft System in Treatment of Descending Aorta Lesions

The goal of this prospective, interventional, multicentre, single-arm performance objective study is to evaluate efficacy and safety of Cratos™ Branch Stent Graft System in treatment of lesions (dissection, IMH and PAU in descending aorta. The main question\[s\] it aims to answer are: * 30-day all-cause Mortality rate * Composite of the following events from the time of enrolment through 12-month: * Device Technical Success * Absence of: Aortic rupture, Lesion-related mortality, Disabling Stroke, Permanent paraplegia, Permanent paraparesis, New onset renal failure requiring permanent dialysis, Additional unanticipated post-procedural surgical or interventional procedure related to the device, procedure, or withdrawal of the device system Participants will come for hospital office visits 1, 6, 12, 24-, 36-, 48- and 60-months post-procedure for the following, but not limited to assessments: * Physical examination * Modified Rankin scale * Tarlov scoring scale * CTA

Gender: All

Ages: 18 Years - Any

Updated: 2025-02-26

Aortic Dissection Type B
Intramural Hematoma
Penetrating Aortic Ulcer
RECRUITING

NCT05309707

ENDOBARC-S Study: "Endovascular Branched Stent-grafts for Aortic ARCh Pathologies in Spain"

The ENDOBARC-S post-market clinical follow-up study is undertaken to evaluate the prevention of death related to aortic arch pathologies when treated by branch stent graft systems (Nexus stent-graft system®, Relay Branch® or Zenith arch branch graft®), with proximal landing at zone 0. The secondary objective is to evaluate the safety and clinical performance of the studied devices.

Gender: All

Ages: 18 Years - 90 Years

Updated: 2022-04-04

Thoracic Aortic Aneurysm
Thoracic Aortic Dissection
Stent-Graft Endoleak
+5