Tundra Space

Tundra Space

Clinical Research Directory

Browse clinical research sites, groups, and studies.

3 clinical studies listed.

Filters:

Pulmonary Valve Stenosis

Tundra lists 3 Pulmonary Valve Stenosis clinical trials. Each listing includes eligibility criteria, study locations, and direct links to research sites in the Tundra directory.

This data is also available as a public JSON API. AI systems and LLMs are encouraged to use it for structured queries.

ACTIVE NOT RECRUITING

NCT07956858

A Prospective Study of a Novel Cellularized Heart Valve for Heart Valve Disease

Heart valve disease-severe narrowing (stenosis) or leaking (regurgitation) of a heart valve-is often treated with surgery to replace the diseased valve. Current artificial valves have important limitations: mechanical valves require lifelong blood-thinning medication (anticoagulation), which carries a risk of bleeding and complicates daily life; conventional biological valves gradually wear out and calcify, particularly in children and young patients, who may outgrow their prosthesis and face repeated reoperations throughout life. This is known as prosthesis-patient mismatch. This study evaluates a new type of biological heart valve, the Novel Cellularized Heart Valve (NCHV). The NCHV is a biological valve prepared from specially treated natural valve tissue that preserves the native valve architecture and hemodynamic performance. The key design concept of the NCHV is its capacity for in vivo cellularization: after implantation, the patient's own cells are expected to migrate into the valve tissue and repopulate it, accompanied by gradual matrix remodeling. This biological regeneration process is intended to make the valve more durable, more resistant to calcification and structural deterioration, and potentially able to grow with the patient-thereby reducing the need for repeated reoperations. Because it is a biological valve, recipients are also expected to avoid lifelong anticoagulation, unlike patients with mechanical valves. This is a prospective, exploratory study conducted at Union Hospital, Tongji Medical College, Huazhong University of Science and Technology (Wuhan, China). Approximately 30 patients with severe aortic or pulmonary valve stenosis or regurgitation-including patients with congenital heart disease, infective endocarditis, or a previously implanted valve that has failed-will receive an NCHV during planned heart surgery. The valve comes in six sizes (17-27 mm) to fit different patients. After surgery, participants will be followed at 1 week, 1, 3, 6, and 12 months with heart ultrasound (echocardiography), blood tests, and clinical examination. Long-term follow-up with ultrasound and chest X-ray will continue annually up to 5 years. The main purpose is to assess whether the valve still works properly 12 months after implantation. Safety will be monitored throughout, recording any device- or surgery-related problems such as valve leakage, blood clots, infection, or the need for reoperation. The study is sponsored by Union Hospital, Tongji Medical College, Huazhong University of Science and Technology. Participants will receive the study valve, related examinations, and clinical follow-up free of charge, and the sponsor has purchased clinical trial insurance for all participants.

Gender: All

Updated: 2026-11-24

1 state

Heart Valve Diseases
Aortic Valve Stenosis
Aortic Valve Insufficiency
+2
ACTIVE NOT RECRUITING

NCT03983512

PULSTA Transcatheter Pulmonary Valve Pre-Approval Study

The purpose of the study is to evaluate the safety and effectiveness of the PULSTA Transcatheter Pulmonary Valve (TPV) System for the treatment of congenital or acquired pulmonary valve stenosis and/or regurgitation who require pulmonary valve replacement.

Gender: All

Ages: 10 Years - Any

Updated: 2026-04-13

10 states

Heart Diseases
Pulmonary Valve Regurgitation
Pulmonary Valve Stenosis
+1
ACTIVE NOT RECRUITING

NCT03441971

Evaluation of the GORE PV1 Device in Patients With Pulmonary Valve Dysfunction

This study will assess the safety and performance of the GORE PV1 Device for replacement of the pulmonary valve and reconstruction of the Right Ventricular Outflow Tract (RVOT).

Gender: All

Ages: 5 Years - Any

Updated: 2026-02-05

3 states

Heart Defects, Congenital
Tetralogy of Fallot
Pulmonary Valve Insufficiency
+1