NCT07920484
A Clinical Study to Collect Real-wordt Data on Safety and Clinical Performance of the VCFix Spinal System for Treatment of Vertebral Compression Fractures of (Suspected) Osteoporotic Origin.
This study is designed as a prospective, post-market, multi-center, single-arm study to collect real-world data of the VCFix Spinal System used in US clinical practice. Approximately 5 centers in the US will enroll subjects with VCF in a non-randomized fashion, and VCFix will be used within its cleared purpose and indications for use. The study has been designed to be methodologically compatible with the EU EXPAND (CIP-VS02-EU) study, thereby aiming for the pooling of data to the EU study. Data pooling will be pursued only as a sensitivity analysis if pre-specified similarity criteria are met. The US study provides meaningful real-world evidence regardless of pooling feasibility. The targeted patient population, assessment schedule, and study endpoints are therefore similar to those of the EU EXPAND study.
Gender: All
Ages: 21 Years - 85 Years
Updated: 2026-11-05
3 states
NCT07242677
Post-market Observational Clinical Study With the Medical Device 'SPHEREPLAST'
This is a retrospective, single-centre, single-arm post-market observational study evaluating the safety and clinical performance of the SPHEREPLAST medical device used in balloon kyphoplasty procedures for the treatment of traumatic and osteoporotic vertebral compression fractures (VCFs). SPHEREPLAST is a titanium alloy (Ti6Al4V-ELI) trabecular sphere system designed to stabilise the vertebral body structure after balloon kyphoplasty, providing immediate mechanical stability and promoting bone ingrowth. The study includes 40 adult patients who have been treated with SPHEREPLAST for thoracolumbar VCFs (A1, A3, OF2, OF3). Data will be collected retrospectively from medical records at four timepoints: pre-operative (baseline), within five days after surgery, at one month, and at one year post-surgery. The primary endpoints are the changes in pain intensity (Numerical Rating Scale, NRS) and disability (Oswestry Disability Index, ODI) between baseline and 1-year follow-up. Secondary endpoints include radiographic outcomes (kyphotic angle, wedge angle, vertebral body height) and the incidence of adverse events related to the device or the procedure. The aim of the study is to assess the real-world clinical efficacy and safety of SPHEREPLAST as an alternative to bone cement in kyphoplasty, with specific attention to pain control, functional recovery, and vertebral stability.
Gender: All
Ages: 18 Years - Any
Updated: 2026-06-01