Clinical Research Directory
Browse clinical research sites, groups, and studies.
9 clinical studies listed.
Filters:
Tundra lists 9 Cataract and IOL Surgery clinical trials. Each listing includes eligibility criteria, study locations, and direct links to research sites in the Tundra directory.
This data is also available as a public JSON API. AI systems and LLMs are encouraged to use it for structured queries.
NCT07158177
Clareon PanOptix Versus AcrySof PanOptix : Prospective Study Comparing Contrast Sensitivity
Retrospective, comparative, interventional, randomized, single-center study, contralateral (the patient's 2 eyes will be implanted: 1 CPO and the other APO) Patients presenting for cataract surgery with a request for presbyopia correction and managed as part of routine clinical practice. The main aim of the study is to demonstrate that contrast sensitivity is better with the Clareon PanOptix (CPO) intraocular lens (IOL) compared with the AcrySof PanOptix (APO) IOL 3 months after implantation.
Gender: All
Ages: 18 Years - Any
Updated: 2026-03-30
1 state
NCT07452042
Postoperative Outcomes of a Toric AddOn Intraocular Lens After Keratoplasty and Cataract Surgery
The aim of this clinical study is to evaluate a toric add-on intraocular lens (IOL) for the correction of high astigmatism in patients who have undergone keratoplasty and cataract surgery. As this patient group often suffers from significant preoperative residual astigmatism, there is a relevant clinical need for effective and safe refractive treatment options. The implantation of a toric add-on IOL in the ciliary sulcus is intended to significantly reduce postoperative astigmatism and improve visual rehabilitation. The study is designed as a prospective, monocentric clinical trial with a limited number of cases, as this is a rare condition with limited availability of suitable patients. It is being conducted in accordance with Section 3 of the Austrian Medical Devices Act (MPG 2021) and is investigating a CE-marked add-on intraocular lens implant used within its intended purpose. The postoperative refractive cylinder serves as the primary endpoint, as it reflects the actual effectiveness of astigmatism correction. The rotational stability of the add-on IOL, which significantly influences refractive precision, is recorded as a secondary endpoint. All study participants will be examined pre- and postoperatively in accordance with applicable medical standards. The results should contribute to the optimization of refractive care after keratoplasty and assess the clinical applicability of toric AddOn IOLs in this specific indication.
Gender: All
Ages: 45 Years - 95 Years
Updated: 2026-03-05
1 state
NCT07294716
Improving Visual Quality in Patients With Irregular Corneas Using Asymmetrical Toric Intraocular Lenses
Cataract surgery in patients with irregular corneas presents unique challenges, primarily due to the high variability in keratometry and corneal tomography measurements, which complicates accurate intraocular lens (IOL) calculations. In these patients, therapeutic options are currently limited to either non-toric IOLs and rigid contact lenses postoperatively or conventional toric IOLs for the reduction of total astigmatism within cataract surgery. While conventional toric IOLs may be beneficial in selected cases with a stable astigmatic pattern and clear axis, their effectiveness is largely limited, as significant irregularity and higher order aberrations reduce predictability, accuracy of formulae, and refractive outcomes. Therefore, the development of a reliable method to reduce total astigmatism - including irregular components - would represent a major advancement, potentially improving both visual function and patient quality of life. The aim of this exploratory study is to evaluate the effectiveness of customized toric intraocular lenses (AMILens Individual, AMIPLANT GmbH, Germany) in reducing total corneal astigmatism in patients with a significant irregular astigmatic component. These lenses are designed to address corneal aberrations up to the 6th Zernike order, thereby extending correction beyond the capabilities of conventional toric IOLs. To our knowledge, no clinical study has yet investigated this novel approach.
Gender: All
Ages: 21 Years - Any
Updated: 2026-01-26
NCT07325162
Development of Optical Biometer
The Helioscope (Cassini Technologies B.V.) is a novel device under development that aims at combining LED-based corneal topography and SS-OCT to provide accurate and fast measurements of both the corneal shape and the ocular biometry. To that end, the hardware and software of the Cassini color-LED topographer (Cassini Technologies B.V.) is combined with a novel SS-OCT device. While the new Helioscope can largely be evaluated using data acquired with healthy eyes, one of its main use-cases is providing input for IOL power formulae for cataract surgery. Thus, it is essential that the device can perform measurements in eyes with (dense) cataract. As cataract changes the optical properties of the crystalline lens and the OCT measurement is optical, this is not a given. This study therefore seeks a dataset of Helioscope measurements performed in eyes with cataract that can be used to develop the software algorithms of the Helioscope.
Gender: All
Ages: 18 Years - Any
Updated: 2026-01-08
1 state
NCT07325188
HUD Surgical Guidance for Toric Alignment
This study aims to assess the accuracy of toric intraocular lens (IOL) alignment axes as calculated and displayed by a novel digital guidance system. In addition, it evaluates the time required to initiate surgical guidance and postoperative refractive astigmatism following toric IOL implantation. This single-surgeon, single-site, prospective, non-invasive observational study evaluated the accuracy of toric IOL alignment axes calculated and displayed by the digital guidance system (Cassini Technologies, B.V.) in 100 eyes. The intraoperatively calculated alignment axes were compared to preoperative measurements to assess their accuracy (in degrees). Postoperative outcomes, including residual refractive astigmatism (diopters) and visual acuity (Snellen), were recorded at 1 month postoperatively.
Gender: All
Ages: 18 Years - Any
Updated: 2026-01-08
1 state
NCT07317661
Effectiveness of a Large Language Model-Based Educational Tool on Intraocular Lens Options
Patients with cataracts disease need to choose what type of artificial lens will go into their eye prior to surgery date. Some lenses are standard and are usually covered by insurance. Other "premium" lenses have various benefits such as reducing the need for glasses but usually require out-of-pocket costs. The combined busy outpatient clinic and complexity of artificial lens choices in the ever-changing world of cataract surgery tends to lead patients confused about their available lens options. There is an abundance of educational material present in premium lenses, however these are limited by accessibility and are standardized at single educational levels. Therefore in the present study, we want to test whether giving patients a short LLM powered AI-guided explanation from Custom GPT from OpenAI of lens options prior to their consultation with their doctor can improve visit efficiency, physician explanation and patient understanding of lens options. We will compare two groups: standard of care versus standard of care plus AI education. The LLM in this study is intended to provide supplemental information about premium intraocular lens(IOLs) options to study participants, and is no means supposed to replace a health care professional in the diagnosis, cure, treatment, and/or mitigation of disease. Study is analogous to giving a verified health pamphlet to a patient for them to view and learn different IOL options, in other words, facilitating patient understanding of their options. The LLM will be trained by several health care professionals and MD specialists to provide sufficient instructions. Sources will include verified online resources and MD information. The investigators hope to learn if a large language model-based educational tool can improve visit efficiency, physician explanation and patient understanding of intraocular lens options. New knowledge of this study could guide how cataract counseling is delivered in the future and may help clinics spend more time on individualized questions instead of repeating generic information.
Gender: All
Ages: 18 Years - Any
Updated: 2026-01-05
1 state
NCT07223866
The Impact of Physiologic Cataract Surgery on Patient Comfort and Medication Usage
The study will pertain to investigating the impact of high vs low IOP on the intraoperative experience and comfort for the patient and surgeon. Our hypothesis is that operating at a more physiological IOP using Unity VCS/CS and Centurion with Active Sentry at a higher, or more traditional IOP will result in significantly less discomfort/pain as assessed by the decreased need for rescue medication and lower VAS scores.
Gender: All
Ages: 60 Years - Any
Updated: 2025-11-10
1 state
NCT07070492
Outcomes of Combined Cataract Surgery With Retinal Surgery for Visually Significant Epiretinal Membrane With Vivity Versus Monofocal Intraocular Lens
To investigate the patient Quality of Life and satisfaction outcomes of combined cataract surgery with retinal surgery for visually significant epiretinal membrane in patients receiving Vivity IOL versus standard monofocal controls.
Gender: All
Ages: 18 Years - Any
Updated: 2025-07-17
NCT07051720
Head-to-Head Comparison of Five Enhanced Depth of Focus IOLs and One Monofocal IOL
Study Goal The goal of this clinical trial is to compare how well four different types of artificial lenses (called intraocular lenses or IOLs) help people see after cataract surgery. The main questions it aims to answer are: Which lens gives the best vision at different distances (far, middle, and close)? How satisfied are patients with their vision after surgery? How often do patients still need glasses after surgery? Who Can Participate Adults aged 22 to 85 years who need cataract surgery in both eyes and meet specific health requirements. Study Design Researchers compared six different lens types: TECNIS Eyhance - designed to improve middle-distance vision AcrySof IQ Vivity - extends the range of clear vision LuxSmart - uses special optics for better depth of focus Rayner EMV - uses gradual light-bending technology for smooth vision transition Eycryl SERT - modifies light focus to extend clear vision range CT ASPHINA 409M - standard single-focus lens (comparison group) Participants chose their preferred lens type after learning about each option's benefits and limitations. What Participants Do? Participants will: Have cataract surgery on both eyes (1-2 weeks apart) Complete vision tests at multiple distances Take contrast sensitivity tests under different lighting conditions Fill out questionnaires about vision quality and daily activities Attend follow-up visits at 1 day, 1 week, 1 month, and 3 months This study helps patients and doctors make informed decisions about which type of artificial lens might work best for individual needs and lifestyle.
Gender: All
Ages: 22 Years - 85 Years
Updated: 2025-07-04
1 state