Tundra Space

Tundra Space

Clinical Research Directory

Browse clinical research sites, groups, and studies.

3 clinical studies listed.

Filters:

Heart Block

Tundra lists 3 Heart Block clinical trials. Each listing includes eligibility criteria, study locations, and direct links to research sites in the Tundra directory.

This data is also available as a public JSON API. AI systems and LLMs are encouraged to use it for structured queries.

RECRUITING

NCT05015660

Conduction System Pacing With Left Bundle Branch Pacing as Compared to Standard Right Ventricular Pacing

High burden right ventricular (RV) pacing has been shown to increase cardiovascular mortality, incidence of heart failure (HF), worsen left ventricular (LV) function and accelerate the development of atrial fibrillation (AF). High percentage ventricular pacing and wider paced QRS in the setting of normal baseline LV ejection fractions have consistently been shown to be independent risk factors for pacing-induced cardiomyopathy. Left bundle branch pacing (LBBP) has emerged as a potential alternative pacing mechanism that may avoid LV dyssynchrony and pacing-induced LV dysfunction by mimicking native electrical conduction.

Gender: All

Ages: 18 Years - Any

Updated: 2026-03-11

1 state

Pacemaker DDD
Heart Block
ENROLLING BY INVITATION

NCT06763549

COR-INSIGHT: Optimizing Cardiovascular and Cardiopulmonary Outcomes with AI-Driven Multiplexed Indications Using COR ECG Wearable

The COR-INSIGHT trial aims to evaluate the effectiveness of Peerbridge COR advanced ambulatory ECG wearables (COR 1.0 and COR 2.0) in accurately and non-invasively detecting cardiovascular and cardiopulmonary conditions using AI-based software (CardioMIND and CardioQSync). The study devices offer non-invasive, multiplexed, AI-enabled direct-from-ECG detection as a novel alternative to traditional diagnostic methods, including imaging, hemodynamic monitoring systems, catheter-based devices, and biochemical assays. Continuous COR ECG data collected in hospital, outpatient clinic, or home settings will be analyzed to evaluate the predictive accuracy, sensitivity, specificity, and performance of these devices in differentiating between screen-positive and screen-negative subjects. The panel of screened indications encompasses a broad spectrum of clinically relevant cardiovascular, cardiopulmonary, and sleep-related diagnostic parameters, which are critical for advanced patient assessment and management. In the cardiovascular domain, the protocol emphasizes the detection and classification of heart failure, assessment of ejection fraction severity, and identification of myocardial infarction, including pathological Q-waves and STEMI. It further addresses diagnostic markers for arrhythmogenic conditions such as QT interval prolongation, T-wave alternans, and ventricular tachycardia, as well as insights into ischemia, atrial enlargement, ventricular activation time, and heart rate turbulence. Additional parameters, such as heart rate variability, pacing efficacy, electrolyte imbalances, and structural abnormalities, including left ventricular hypertrophy, contribute to comprehensive cardiovascular risk stratification. In the non-invasive cardiopulmonary context, the protocol incorporates metrics like respiratory sinus arrhythmia, cardiac output, stroke volume, and stroke volume variability, providing critical insights into hemodynamic and autonomic function. The inclusion of direct-from-ECG metrics for sleep-related disorders, such as the apnea-hypopnea index, respiratory disturbance index, and oxygen saturation variability, underscores the protocol's utility in addressing the intersection of cardiopulmonary and sleep medicine. This multifaceted approach establishes a robust framework for precision diagnostics and holistic patient management. The COR 1.0 and COR 2.0 wearables provide multi-lead ECG recordings, with COR 2.0 offering extended capabilities for cardiopulmonary metrics and longer battery life (up to 14 days). COR 2.0 supports tri-modal operations: (i) Extended Holter Mode: Outputs Leads II and III, mirroring the functionality of COR 1.0 for broader ECG monitoring applications. (ii) Cardiopulmonary Mode: Adds real-time recording of Lead I, V2, respiratory impedance, and triaxial accelerometer outputs, providing advanced cardiopulmonary insights. (iii) Real-Time Streaming Mode: Streams data directly to mobile devices or computers via Bluetooth Low Energy (BLE), enabling real-time waveform rendering and analysis. The COR 2.0 units are experimental and not yet FDA-cleared. Primary endpoints include sensitivity (true positive rate) \> 80%, specificity (true negative rate) \> 90%, and statistical agreement with reference devices for cardiovascular, cardiopulmonary, and sleep metrics. Secondary endpoints focus on predictive values (PPV and NPV) and overall diagnostic performance. The study employs eight distinct sub-protocols (A through H) to address a variety of cardiovascular, cardiopulmonary, and sleep-related diagnostic goals. These sub-protocols are tailored to specific clinical endpoints, varying in duration (30 minutes to 14 days) and type of data collection. Up to 15,000 participants will be enrolled across multiple sub-protocols. Screening ensures eligibility, and subjects must provide informed consent before participation. Dropouts and non-compliant subjects will be excluded from final analyses.

Gender: All

Ages: 18 Years - Any

Updated: 2025-01-08

1 state

Cardiopulmonary Failure
Myocardial Infarction (MI)
Heart Decompensation
+38
RECRUITING

NCT06055751

Long Term Evaluation of Cardiac Arrhythmias After Transcatheter Aortic Valve Implantation -The LOCATE Registry

The purpose of the Long term Evaluation of Cardiac Arrhythmias after Transcatheter Aortic Valve Implantation (LOCATE) Registry is to perform long-term ambulatory monitoring of patients with severe aortic stenosis who undergo trans-catheter aortic valve implantation (TAVI) and develop new onset conduction system abnormalities post-procedure that do not require urgent permanent pacemaker (PPM) implantation. The primary objectives of this study are to assess the incidence of late onset heart block necessitating PPM implantation and to evaluate the incidence of new onset atrial fibrillation (AF) following TAVI. This study aims to provide valuable insights into the long-term cardiac health of TAVI patients and inform the development of improved treatment strategies for aortic stenosis patients with conduction system abnormalities.

Gender: All

Ages: 18 Years - Any

Updated: 2024-10-16

1 state

Aortic Stenosis
Atrial Fibrillation New Onset
Heart Block